| KEY | DESCRIPTION |
|---|---|
| CACT |
Closed Atmosphere Cooling Tunnel. The CACT is a 76.2 cm (30
inch) long, high efficiency heat exchanger that reduces the temperature of the product.
Inside the CACT, process gas flows through air rakes arranged two above the belt to cool
the product to a safe temperature. To expedite heat removal, fans outside the chamber
force ambient room air over the heat sink finned surfaces on the outside of the tunnel.
Multiple tunnels may be joined end-to-end to obtain required cooling. Standard
on many furnace configurations, option available on most furnaces.
|
| CAWC |
Closed Atmosphere Water Cooled Tunnel. The CAWC is a 76.2 cm
(30 inch) long, high efficiency heat exchanger that reduces the temperature of the product,
but without externally mounted heat sink cooling fans. Instead, water flowing through chambers
above and below the tunnel removes heat from the tunnel walls without adding to the heat
load in the clean room. Includes OI integrated outlet water temperature sensors and alarms.
Requires water supply and drain. Multiple tunnels may be joined to obtain required
cooling. Upgrade from CACT. Standard on many furnace configurations,
option available on most furnaces.
|
| CB-1 |
Circuit Breaker. Three phase circuit breaker.
Required for UL approval. Option available on most furnaces.
|
| CDA-L |
CDA Lockout. Manual lockout for CDA supply line, 1724
kPa, 250 psi. Option available on most furnaces.
|
| CDA-S |
CDA Auto Shutdown. Automatically shuts off CDA supply
after actual furnace Power OFF to reduce compressor load and gas consumption. Includes
timed delay to assure clearing of all process gas and emissions from furnace chamber.
Note: furnace control delays actual Power OFF until furnace cools to 100 C.
Option available on most furnaces.
|
| CFL |
Cabinet Fans, Lower. Provides a high air volume impeller
fan, located below the belt, to remove excess heat from the product and cabinet interior.
Used with CMB30 and CMB45 Cross-flow Fan Cooling Modules. Standard on all furnace configurations
with
CMB30 or
CMB45 modules.
|
| CM |
Turbulent Air Cooling Module. Provides a 76.2 cm (30 inch)
long, fan-driven cooling module consisting of two rows of 3 m3/min (106 cfm)
fans that force ambient air over all surfaces of the product. This module can be used to
bring massive or high‑speed product to handling temperature quickly. Controlled atmosphere
processes should be reviewed to assure that the product is below its oxidation temperature
before reaching the air cooling. The fan speed is controlled via the control console.
Standard on some furnace configurations, option available on most furnaces.
|
| CMB30 |
Forced Air Cooling Module. Supplies fan-driven ambient air for
rapid convection cooling of product on the belt. This 76.2 cm (30 inch) long, forced air
cooling module uses two top-mounted cross-flow 13.3 m3/min (471 cfm) fans to
force ambient air into a plenum assembly located above the belt, resulting in a downward
laminar flow over the entire surface area of the belt directly under the cooling module.
Controlled atmosphere processes should be reviewed to assure that the product is below its
oxidation temperature before reaching the air cooling. Fan speed is controlled via the control
console. Multiple modules may be joined to obtain required cooling. Standard on
some furnace configurations, option available on most furnaces.
|
| CMB45 |
Forced Air Cooling Module. Supplies fan-driven ambient air for
rapid convection cooling of product on the belt. This 1.143 m (45 inch) long, forced air
cooling module shall use three top-mounted cross-flow 13.3 m3/min (471 cfm) fans
to force ambient air into a plenum assembly located above the belt, resulting in a downward
laminar flow over the entire surface area of the belt directly under the cooling module.
Controlled atmosphere processes should be reviewed to assure that the product is below its
oxidation temperature before reaching the air cooling. Fan speed is controlled via the control
console. Multiple modules may be joined to obtain required cooling. Standard on
some furnace configurations, option available on most furnaces.
|
| CWWC |
Cold Wall Water Cooling Module. High efficiency, 50.8
cm (20 inch) long, water-cooled module that improves heat transfer from cooling tunnel,
more rapidly reducing the temperature of the product. Includes OI integrated inlet
and outlet water temperature sensors and alarms. Requires water supply and drain.
Multiple modules may be joined to obtain required cooling. Upgrade from CACT. Standard
on some furnace configurations, option available on most furnaces.
|
| CXE15 |
Entrance Conveyor Extension. Extends load station at the
entrance of the furnace or dryer. Adds 0.381 m (15 inches) to length of furnace.
Option available on most furnaces.
|
| CXX15 |
Exit Conveyor Extension. Extends unload station at the
exit of the furnace or dryer. Adds 0.381 m (15 inches) to length of furnace.
Option available on most furnaces.
|